Reports until 15:41, Thursday 18 December 2025
H1 SUS (PSL, SUS)
rahul.kumar@LIGO.ORG - posted 15:41, Thursday 18 December 2025 - last comment - 07:33, Friday 19 December 2025(88599)
HAM1 vent work - JM1 and JM3 plugged in to the electronics chain - OLC re-taken and offsets applied on the medm screen

Betsy, Rahul

We found that SUS JM1 had a faulty quadrupus cable, which we replaced it today. Next, I took OLC for both JM1 and JM3 in HAM1 chamber. I applied the offsets, gains and then centered the BOSEMs - and they look good. Next, I will start checking the health of the electronics chain and the suspension itself (i.e. by taking the transfer function measurements).

The offsets and gain for JM1 is recorded in this screenshot - accepted in the SDF (safe).

The offsets and gain for JM3 is recorded in this screenshot - accepted in the SDF (safe).

Images attached to this report
Comments related to this report
rahul.kumar@LIGO.ORG - 15:54, Thursday 18 December 2025 (88600)

Oli, Rahul

We started damping both the suspensions - found that the voltmons were not working (Dave found that their gains were set to zero). 

With voltmons ON, both the suspensions were damping fine - no overflows on this 28bit DAC. 

rahul.kumar@LIGO.ORG - 15:59, Thursday 18 December 2025 (88601)

Adding pictures of JM1 and JM3 I took today.

Images attached to this comment
corey.gray@LIGO.ORG - 07:33, Friday 19 December 2025 (88607)EPO

Tagging EPO for JM photos