Below is a summary of the available controls on SEI platforms, for PRMI. Platforms should run under their preferred configuration at all time.
HAM1:
HAM2:
-
ISI: Lv3 Isolation, fed by 01_28 generic blend.
-
HEPI: Position loops ON
HAM3:
-
ISI: Lv3 Isolation, fed by 01_28 generic blend.
-
HEPI: Position loops ON
BS:
-
ISI: Lv3 Isolation, fed by:
-
Stage 1: T250mHz blend, with T100mHz_N0.44 on X and Y
-
Stage 2: 250mHz
-
HEPI: Position loops ON
ITMY:
-
ISI: Lv3 Isolation, fed by:
-
Stage 1: T250mHz blend, with T100mHz_N0.44 on X and Y
-
Stage 2: 250mHz
-
HEPI: Position loops ON
ETMX:
-
ISI: Lv3 Isolation, fed by:
-
Stage 1: T250mHz blend, with T100mHz_N0.44 on X and Y
-
Stage 2: 250mHz
-
HEPI: Locked
ITMX - Commissionning to be completed
-
ISI: Damping
-
HEPI: floating
Note: The HEPI-BS position loops are in the second set of filter banks. One should use the isolate BS lv2 command button, instead of lv1, for this chamber only.