Displaying report 1-1 of 1.
Reports until 16:46, Monday 12 January 2026
H1 CDS
david.barker@LIGO.ORG - posted 16:46, Monday 12 January 2026 - last comment - 16:59, Monday 12 January 2026(88741)
h1lsc model restart, DAQ restart, EDC move, add JAC_LOCK guardian channels to EDC.

Daniel, Ryan S, Erik, Jonathan, Dave

In preparation to tomorrow's work on h1susauxb123 we decided to move the EDC from here to h1susauxh56. We did this at the same time the DAQ was being restarted for:

1 Daniel's new h1lsc model

2 Adding Ryan's JAC_LOCK guardian node to EDC

The EDC move had a few configuration issues which were quickly resolved. There were no issues with the h1lsc restart.

 

Comments related to this report
david.barker@LIGO.ORG - 16:59, Monday 12 January 2026 (88742)

Mon12Jan2026
LOC TIME HOSTNAME     MODEL/REBOOT
14:51:52 h1lsc0       h1lsc       <<< Daniel's latest model


14:56:29 h1susauxh56 h1edc[DAQ] <<< EDC move to susauxh56
15:06:45 h1susauxh56 h1edc[DAQ]


15:11:30 h1daqgds1    [DAQ] <<< DAQ restarts
15:15:34 h1daqdc1     [DAQ]
15:15:41 h1daqdc1     [DAQ]
15:15:47 h1daqfw1     [DAQ]
15:15:47 h1daqnds1    [DAQ]
15:15:47 h1daqtw1     [DAQ]
15:16:32 h1daqgds1    [DAQ] 
15:25:15 h1daqnds0    [DAQ]
15:25:26 h1daqfw0     [DAQ]
15:25:27 h1daqgds0    [DAQ]
15:25:29 h1daqfw0     [DAQ]
15:25:29 h1daqnds0    [DAQ]
15:25:29 h1daqtw0     [DAQ]
 

Displaying report 1-1 of 1.