CDS BS move and LIGO-DAC upgrade

Fil, Marc, Richard, Jeff, Oli, Erik, EJ, Jonathan, Dave:

WP12962 Move BS for upgrade to BBSS. WP12901 Upgrade ITM to LIGO-DAC

On Tuesday 13Jan2026 we reconfigured the BSC1,2,3 and HAM3,4 suspensions to move the BS control from h1susb123 to h1sush34 and upgrade the ITM test mass suspensions to use the new LIGO-DACs. Associated changes were also made to these systems' SUS-AUX frontends.

Frontend Computer Renaming:

old name new name
h1susb123 h1susb13
h1sush34 h1susb2h34
h1susauxb123 h1susauxb13
h1susauxh34 h1susauxb2h34

Prep Work:

The 4 LIGO-DACs used for this upgrade were calibrated in the EE shop and FE tested on the DTS.

The EDC was moved from h1susauxb123 to h1susauxh56

Upgrade:

The h1susb123 and h1sush34 suspensions were SDF reconcilled and put into their safe state.

The SWWD seismic systems were put into an infinite bypass.

All 4 front end were powered down and work on their IO Chassis, AAs and AIs started.

h1susb13 IO Chassis

8 20bit-DACs removed, 2 LIGO-DACs added.

Removed 20bit-DACs

20bit-DAC 18/20bit-DAC Interface Card
200217-17 S1200228
220218-29 S1200227
210303-49 S1200224
210303-35 S1200219
210303-22 S1200220
200217-19 S1200221
210303-57 S1200226
220218-08* S1200229

* 20bit-DAC 220218-08 installed in new h1susb2h34 chassis.

New Adnaco Layout

Adnaco slot Card [interface]   Adnaco slot Card [Interface]
A1-1 LIGO Timing Card   A3-1 empty
A1-2 empty   A3-2 empty
A1-3 ADC0 (orig)   A3-3 empty
A1-4 LIGO-DAC0 S2500457 [010]   A3-4 empty
         
A2-1 ADC1 (origin)   A4-1 BIO0 (orig)
A2-2 LIGO-DAC1 S2500448 [011]   A4-2 BIO1 (orig)
A2-3 empty   A4-3 BIO2 (orig)
A2-4 empty   A4-4 empty

h1susauxb13 IO Chassis

Removed last 2 ADCs, installed them in h1susauxb2h34 IO Chassis. ADC count went from 8 to 6.

h1susauxb2h34 IO Chassis

Added the 2 ADCs from h1susauxb13 in next available slots. ADC count went from 6 to 8.

ADC ADC Card Interface Card
ADC6 110128-11 S1102417
ADC7 110128-03 S1301433

h1susb2h34 IO Chassis

Original layout skipped Adnaco slot A2-4. Reviewed as-built drawings and alog but could not find why this slot was not being used. Assuming that there was something wrong with this slot I replaced the second Adnaco backplane

Suspect Backplane (removed) C8610415
New Backplane (installed) C8610796

Original layout was:

2 ADC, 5 18bit-DAC, 1 20bit-DAC, 2 BIO.

Update: keep the 2 ADCs, remove all 5 18bit-DACs, keep the 1 20bit-DAC and add a second 20bit-DAC, add 2 LIGO-DACs and add a third BIO.

Table of removed 18bit-DACs + IF

18bit-DAC Interface Card
110425-10 S1104013
101208-71 S1104017
110425-04 S1104014
110425-09 S1104023
110425-46 *

* Because the 18bit and 20bit DACs use the same Interface card, this IF card was left in the chassis for the second 20bit-DAC

New Adnaco layout

Adnaco slot Card [Interface]   Adnaco slot Card [Interface]
A1-1 LIGO Timing Card   A3-1 empty
A1-2 empty   A3-2 empty
A1-3 ADC0 (orig)   A3-3 empty
A1-4 20bit-DAC0 (orig)   A3-4 empty
         
A2-1 ADC1 (orig)   A4-1 BIO0 (orig)
A2-2 20bit-DAC1 *   A4-2 BIO1 (orig)
A2-3 LIGO-DAC0 S2500454 [012]   A4-3 BIO2 ADRBS96001188
A2-4 LIGO-DAC1 S2500442 [013]   A4-4 empty

* 20bit-DAC1 ss0218-08 repurposed from h1susb123 surplus.

Timing Card Firmware Upgrade (Marc)

All 4 IO Chassis Timing Cards had a firmware upgrade. This was essential for the control frontends, which would not be able to drive the LIGO-DACs without the new firmware. The SUS-AUX TCs were upgraded as part of the general upgrade of all frontends.

  Tming Card Firmware Version
old 1 - 0x1f0
new 2 - 0x635

 

Model Changes and Current Status

h1iopsusb13 New model name, installed but needs SWWD review
h1susitmx Not running, being reworked
h1susitmy Not running, being reworked
h1susitmpi Not running, being reworked
h1iopsusb2h34 New model name, installed but needs SWWD review
h1susbs New location, not running, being reworked
h1susmc2 Not running, being reworked
h1suspr2 Not running, being reworked
h1sussr2 Not running, being reworked
h1iopsusauxb13 New model name, running and complete
h1susauxb13 Temporary model running, being reworked
h1iopsusauxb2h34 New model name, running and complete
h1susauxb2h34 Temporary model running, being reworked

All models are being built with RCG5.5.2, which is needed to drive more than 1 LIGO-DAC.