Reports until 14:09, Wednesday 14 January 2026
H1 SUS (CDS, IOO, ISC, SUS)
jeffrey.kissel@LIGO.ORG - posted 14:09, Wednesday 14 January 2026 - last comment - 13:58, Thursday 22 January 2026(88765)
CER Hardware/Electronics Changes To Convert SUSB123 and SUSH34 to SUSB13 and SUSH34 Complete; User Model Software Changes Commencing
J. Kissel, F. Clara, O. Patane, M. Pirello, D. Barker
ECR E2500296, E2400409
WP 12962
D2300401 (for susb13) and D2300383 (for susb2h34)
G2301306 -- PARTII 2023 plan, PARTII Update 

We've completed all electronics hardware moves, cabling/recabling and new installations that we plan to do on SUS MC2, PR2, SR2, BS, and the future LO1 and LO2 for now.

Given that this change to the electronics is somewhere in between versions of the D2300401 h1susb13 and D2300383 h1susb2h34 wiring diagrams -- the interim configuration we're in now that 

    Does have
        - susb2h34 and susb13, as well as susauxb13 and susauxb2h34 with all their ADC and DAC cards, as they will be in O5.
        - All of the BS electronics have been moved from SUS-C5/SUS-C6 to SUS-C1/SUS-C2, and their CER cabling dragged along with it
        - all AI chassis driven by 28-bit 32CH DACs (7 in total) have been converted from a pair of D1000305 2x8CH DAC AIs to a pair of D2500353 1/2x32CH DAC AIs.
        - ITM AA chassis inputs (both OSEM sensors, optical levers, and CD monitors) and AI chassis outputs have been re-arranged such that the grouping is far more sensibly arranged and modular per QUAD.
    
    Doesn't have 
        - BBSS-like BS TOP mass converted to QOSEMs
        - BBSS-like BS M3 OSEM sensing and actuation electronics
        - Any LO1 or LO2 electronics
        - The BS optical lever in its final AA chassis position (because the BS TOP mass OSEMs still need that spot)
        
        - Any changes to the field cabling
            - the BS M1 satamps, M2 satamps, and M3 optical lever whitening chassis are all still in SUS-R6)
-- we planned /documented all of this work on google slides -- see PARTII Update -- which is linked in the abstract of G2301306.

We'll add more details, gotchas, and pictures below in the comments.
Comments related to this report
oli.patane@LIGO.ORG - 13:58, Thursday 22 January 2026 (88856)

Here's some overview diagrams of how the racks were set up before (O4 configuration) and how they are set up now. SUSB13 (SUS-C5/C6) is in its final O5 configuration but SUSB2H34 (SUS-C1/C2) is in an interim ("No QOSEMs/BBSS") configuration. These diagrams are also available in the PARTII Update linked in the original post.

SUSB13
O4 Configuration (SUSB123)
Now - O5 Configuration (SUSB13)

SUSB2H34
O4 Configuration (SUSH34)
Now - "No QOSEMs/BBSS" Configuration (SUSB2H34)

Images attached to this comment