Displaying report 1-1 of 1.
Reports until 16:42, Thursday 15 January 2026
H1 SQZ
karmeng.kwan@LIGO.ORG - posted 16:42, Thursday 15 January 2026 (88777)
HAM7 alignment progress

[Sheila, Karmeng]

Today we checked and managed to reduce some of the saturation on ZM4, and offload it onto ZM6. The changes were undone for now.

We briefly did the power budget check, but the power measured at the output of the SFI1 is fluctuating (between 0.79mW to 1.6mW) when the input to SFI1 is at 0.79mW. The power is stable down the propagation (after AP1 and SFI2), unsure what causes the fluctuation. Will continue to look into this tomorrow.

We also did an OMC scan, the pink trace is the scan when ZM4 is in its original setting (YAW: 1779.5), and the red trace is correspond to ZM4 misalignment (YAW: 1769.5).