Reports until 18:04, Thursday 15 January 2026
H1 DAQ
jonathan.hanks@LIGO.ORG - posted 18:04, Thursday 15 January 2026 - last comment - 15:13, Friday 16 January 2026(88778)
End of day daqd restarts and issues

We had some hiccups in our end of day daqd restart.

1. There were duplicate channels between the h1susb13 and h1susb2h34 models.  We are not sure how these got through, the daqd should have crashed on startup with an error message.  We found this as it caused issues on the test framewriter on h1daqfw2.

2. After Oli removed the old block from h1susb13 we found that there were some GDS broadcaster channels that were dropped that probably shouldn't be.  We removed them from the broadcast list in order to get the daqd to run.  Listing the channels here so that they can be added back in tommorow:

Comments related to this report
jonathan.hanks@LIGO.ORG - 15:13, Friday 16 January 2026 (88791)

After looking through the code, this is an old bug.  It has been fixed for a while.  The daqd had not been updated with the rcg for a long time due to no feature changes.

We should do a daqd package upgrade next week.