matthewrichard.todd@LIGO.ORG - posted 12:12, Friday 16 January 2026 (88785)
ISS Noise Budget for O4c

M. Todd, C. Cahillane, K. Kawabe


In the last quarter of 2025, I was running a bunch of injections to the various ASC DOFs of the IMC, and looking at the response in the ISS --- this was all in an effort to explain the various features in the witnessed RIN from the out of loop diodes of the ISS array, or in other words create a noise budget for the ISS. In short, I believe we are IMC ASC limited below 5Hz while acheiving the shot noise limit from 20-1000Hz.

There are some peaks in the witnessed RIN that are not in the in-loop ASD, suggesting it is some noise being imposed by the loop itself. Further measurements will try and explore the source of some of these, particularly the ones around 18 and 24 Hz, with a suspicion of the IMs motion.


I wanted this alog to serve as a reference for where all the data lives for these measurements, as well as the code and noise budget plot. Note, the ISS_OUTER and INNER rin channels are saved with quick_psd, but the gpstimes are recorded in the table below.

For the projections, a transfer function is measured during the excitation of the measured DOF --- looking at the TF from the best witness channel to the ISS OUTER, and then that transfer function is applied to the witness during the quiet time when there is no excitation.

Measurement GPS Time File Location Notes
ISS OUTER RIN
1446823543 
/ligo/home/matthewrichard.todd/Projects/imc_injections/dtt_injections/quiet_data_iss_outer_rin.txt Taken with quick_psd and then saved
ISS INNER RIN 1446823543 /ligo/home/matthewrichard.todd/Projects/imc_injections/dtt_injections/quiet_data_iss_inner_rin.txt Taken with quick_psd and then saved
IMC PZT Pitch projection 1446912665 /ligo/home/matthewrichard.todd/Projects/imc_injections/dtt_injections/pzt_pit_injection_1_15_Hz.xml

Injection Band: 1-15Hz

Best Witness: WFS_A_PIT

IMC PZT Pitch projection 1445107725 /ligo/home/matthewrichard.todd/Projects/imc_injections/dtt_injections/pzt_pit_injection_15_1000_Hz.xml

Injection Band: 15-1000Hz

Best Witness: WFS_A_PIT

IMC PZT Yaw projection 1446900349 /ligo/home/matthewrichard.todd/Projects/imc_injections/dtt_injections/pzt_yaw_injection_1_15_Hz.xml

Injection Band: 1-15Hz

Best Witness: WFS_A_YAW

IMC PZT Yaw projection 1445108720 /ligo/home/matthewrichard.todd/Projects/imc_injections/dtt_injections/pzt_yaw_injection_15_1000_Hz.xml

Injection Band: 15-1000Hz

Best Witness: WFS_A_YAW

IMC DOF 1 Pitch projection

1445698453 /ligo/home/matthewrichard.todd/Projects/imc_injections/dtt_injections/imc_dof_1_pit_injection_1_4_Hz.xml

Injection Band: 1-4Hz

Coherent Band: 0.2-5Hz

Best Witness: WFS_B_PIT

IMC DOF 1 Yaw projection

1445698453 /ligo/home/matthewrichard.todd/Projects/imc_injections/dtt_injections/imc_dof_1_yaw_injection_1_4_Hz.xml

Injection Band: 1-4Hz

Coherent Band: 0.2-5Hz

Best Witness: WFS_B_YAW

IMC DOF 2 Pitch projection

1445698453 /ligo/home/matthewrichard.todd/Projects/imc_injections/dtt_injections/imc_dof_2_pit_injection_1_4_Hz.xml

Injection Band: 1-4Hz

Coherent Band: 0.2-4Hz

Best Witness: MC2_TRANS_PIT

IMC DOF 2 Yaw projection

1446303221 /ligo/home/matthewrichard.todd/Projects/imc_injections/dtt_injections/imc_dof_2_yaw_injection_1_4_Hz.xml

Injection Band: 1-4Hz

Coherent Band: 0.2-5Hz

Best Witness: WFS_A_YAW

       

ISS Noise Budget O4c