Reports until 16:05, Tuesday 27 January 2026
H1 CDS (ISC)
filiberto.clara@LIGO.ORG - posted 16:05, Tuesday 27 January 2026 (88922)
Field Racks ISC-R5 and ISC-R6

WP 12991
WP 12994
D1200196 ISC-R5 Layout
D2400300 - ISC-R6 Layout
D1900511 - ISC/SQZ Wiring Diagram

In preparation for the installation of BHD, the following work was done to the HAM6 field racks:

1. ISC-R3 is now on its own set of power supplies for ±18V
2. ISC-R5 and ISC-R6 share a set of power supplies for ±18V
3. ISC-R3, ISC-R5, and ISC-R6 share a set of power supplies for ±24V
4. ISC-R5 was updated to D1200196-v15
5. ISC-R6 was updated to D2400300-v1

Racks are not complete. Missing electronics will be installed when available.

F. Clara, D. Sigg