S. Muusse, M. Todd


Lens realigned on X-arm CHETA table for corrected focal lengths and the beam profiled which had better agreement with the model. ITM beam size from fit are much closer to ideal beamsize on ITM (≈ 52.7mm).


Fit for profile after L2 vs model 

  Fit Model
w0x,w0y  [um] [970.5 ± 28.7, 940.8 ± 23.3] [1023.9,  981.71]
z0x,z0y [mm] [-1078.1 ± 32.0, -901.9 ± 22.5] [1.046 , 0.928 ]
qx [mm] 1.078 ± 32.0 + 0.643 ± 38j 1.046 + 0.708j 
qy [mm] 0.902 ± 22.5 + 0.604 ± 30j 0.928 + 0.651j 
Beam radii at ITM [mm] [54.442, 55.885]   [52.311, 54.385]

Beam radii at ITM is foudnfrom fit by propagating the fit q to the ITM.

Images attached to this report