IMC scan for mis-polarization measurement

LIGO git repo: https://git.ligo.org/masayuki.nakano/lho_jac_installation/-/tree/2bd2518c1e08635017066b16d4b7c5f752ed0ea5/

Summary

We performed IMC scans to evaluate mis-polarization and spatial mode content associated with the JAC installation. First, reference measurements were taken before the EOM installation using intentional MC2 yaw/pitch misalignment to robustly identify higher-order modes. After the EOM installation, the same type of IMC scan was repeated. The post-EOM measurement shows that the mis-polarization signature observed before the EOM is strongly reduced, while a significantly larger higher-order mode content is present, indicating substantial mode mismatch in the current post-installation layout.

Procedure

After the EOM installation, a representative post-EOM scan was taken with the same scan settings. For this measurement, the IMC transmission whitening gain was set to 30 dB. Unfortunately, the GPS start time for the post-EOM dataset was not logged at the time of measurement.

Notes