Mode-matching Analysis Based on As-built HAM1 Layout (post-EOM)

Summary

Based on the post-EOM IMC scan results showing significant mode mismatch, we performed a detailed mode-matching analysis using the as-built HAM1 layout. Optics positions were identified from chamber photos, beam traces were reconstructed, and the expected IMC mode-matching and higher-order mode fractions were calculated. The analysis shows that the dominant source of the mode-mismatch degradation is a longitudinal shift of JM2 introduced by the EOM installation, and that moving JM2 can effectively recover good mode matching.

Procedure

Notes

Result

Proposal (Practical Implementation)

  1. Install one iris in the reflected beam immediately after JM3, and place another iris on the IOT2L table.
  2. Change the longitudinal position of JM2.
    • The target position will be documented in a follow-up figure.
    • After moving JM2 and roughly passing the beam through the irises, fix the mount using dog clamps.
    • Replace the JM2 mirror at this stage.
  3. Perform alignment using the iris just after JM3 and the iris after the periscope.
    • Use JM2 to center the beam on the first iris and JM3 to center on the output iris.
    • This procedure is expected to provide sufficient alignment accuracy; if needed, the IOT2 table can be used for further refinement.
  4. Repeat the IMC scan measurement to confirm the improvement in mode matching.

 