Oli, Rahul, Tony, Marc, Fil, Daniel, Dave.
At 15:41 we restarted the h1susham1 model as part of the PM1 noise investigation. This did not change anything.
Later (16:40) Marc and Fil found that the problem was a dead power rail in the PM1 coil driver.