IMC loop gain and power checks this morning

Sheila, Matt, Masayuki

This morning Matt and I brought the SR785 back to the PSL racks to check the IMC OLG.  We think that the increase in IMC gain that's needed to restore the ugf is consistent with what's expected (so the modulation depth for 24MHz is similar to before the JAC work), but there is only about 1/4 of the expected power on IM4 trans sum.  

  before JAC install  today  
power into HAM1 H1:IMC-PWR_IN_OUT16 2W 1W  
H1:IMC-REFL_SERVO_IN1GAIN 5dB 11dB we would need about 15dB to restore 35kHz ugf, which is consistent with what's expected for the power drop.  
IMC ugf 35kHz 23.3kHz (see attachment)  
MC2 trans 310 counts 90 counts consistent with 60% HAM1 throughput measured with a power meter (extra loss due to temporary mirror for JM3)
IM4 trans nsum 1.8W 0.1W We should expect 0.54W here if alignment was the same as Nov 2025
AS_C with single bounce power into HAM6   0.6mW expect 1W *0.6 HAM1 throughput * 0.03 PRM * 0.25 BS * 0.3 SRM = 1.3mW, so we are seeing half the light we expect in HAM6

The misalignment onto IM4 trans might be explained by HEPI being locked, when this shift happened in December the alignment onto IM4 trans QPD shifted so that the beam was all on the upper two quadrants. 

 