Displaying report 1-1 of 1.
Reports until 20:38, Tuesday 10 December 2013
H1 SUS
arnaud.pele@LIGO.ORG - posted 20:38, Tuesday 10 December 2013 - last comment - 11:32, Wednesday 11 December 2013(8901)
Tip Tilts progress

[Mark B Chris W Arnaud]

After modifying the tip tilts model this afternoon, I adapted the adl files to match with the new channel names, in order to resurrect the medm screens. The filterfile, as well as the snap file were also adapted. The only thing missing in order for the system to work is to connect the masterswitch, which will be done tomorrow morning. Other than this, everything seems fine, cf screenshot

Details of the process :

* Created a htts folder in /opt/rtcds/userapps/release/sus/common/medm/
* Copied the 42 adl files located in /opt/rtcds/userapps/release/asc/common/medm/asctt in the new htts folder
* Modified their filename from ASC_CUST_TIPTILT* to SUS_CUST_TIPTILT*
* Modified the content of each of them by changing the ASC/asc occurences to SUS/sus and ASCTT/asctt to SUSHTTS/sushtts (except for the IOP channels which were unchanged)
* Modified the sitemap to point out to the correct adl files
* Modified the H1SUSHTTS.txt filterfile that has been generated when installing the model this afternoon, to make it match with the old H1ASCTT.txt filterfile thanks to some magic tricks from Chris
* Created a softlink H1SUSHTTS.txt -> /opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSHTTS.txt

Bonne nuit !

Images attached to this report
Comments related to this report
arnaud.pele@LIGO.ORG - 11:32, Wednesday 11 December 2013 (8905)

Now the master switch is connected, RMs medm screens are functioning, as well as the damping

Displaying report 1-1 of 1.