Displaying report 1-1 of 1.
Reports until 15:30, Thursday 05 February 2026
H1 AOS
matthewrichard.todd@LIGO.ORG - posted 15:30, Thursday 05 February 2026 (89056)
OMC scans -- 2026-02-05

M. Todd, S. Muusse, C. Compton, S. Dwyer


Today we ran some more OMC scans with the ITM ring heaters on. At first we ran the OMC scan with the 9/45 sidebands on, single bounce off ITMX. Then we turned sidebands off and did both ITMX and ITMY.

Measurement Time Test Masses CO2 [W] Ring Heater (per segment) [W] SR3 [W] OM2 [W] FOM Notes
OMC Scan - Single Bounce off of ITMX 1454352294 Cold 0 2.45  0 0 Mismatch = 20.2% Sidebands on
OMC Scan - Single Bounce off of ITMX 1454359702 Cold 0 2.45  0 0 Mismatch = 23.9% Sidebands off
OMC Scan - Single Bounce off of ITMY 1454360545 Cold 0 2.00 0 0 Mismatch = 22.7% Sidebands off
Images attached to this report