HAM3 Annulus Ion Pump Replacement

(Jordan V., Gerardo M.)

-Late entry

On Friday we removed and replaced the ion pump for HAM3.  We replaced the copper gasket twice, the first gasket seal had a bad leak, it was hard to see the mating surfaces due to visibility issues (laser safety goggles and not enough light).
After installing a second gasket, we started pumping down the annulus system and pressure went down fast.  Last pressure reading at the aux-cart was 4.63x10^-05 Torr.
BTW, we have other 4 (four) ion pumps to replace.

Images attached to this report
Comments related to this report
corey.gray@LIGO.ORG - 09:23, Thursday 12 February 2026 (89129)EPO

EPO taggin'.

gerardo.moreno@LIGO.ORG - 17:24, Friday 13 February 2026 (89151)VE

(Jordan V., Gerardo M.)

After a couple of days of "assisted" pumping, the annulus system isolation valve was closed.  After a day of solo pumping the ion pump was able to maintain the annulus pressure at nominal.  Now the aux-cart, can turbo and hoses were removed, pressure looks good.