Displaying report 1-1 of 1.
Reports until 13:03, Tuesday 10 February 2026
H1 CAL
dripta.bhattacharjee@LIGO.ORG - posted 13:03, Tuesday 10 February 2026 - last comment - 16:32, Tuesday 10 February 2026(89103)
PCAL EX Endstation measurement

Tony and myself are here at EX finishing up the EX ES measurement.
We did find that the excitations were turned on at GPS time: 1454787583, but no excitations came through the channel PCAL_EX_SUM_MON until after we were finished.
We did however have to restart a measurement due to a gap in the data. measurement #7 Both beams on the Working standard inside the RX module.
What we did not realize until after, was that at the time the gap happened the excitation switch INJ_MASTER_SW was turned back on and remained on for the remainder of the measurement. 

Also Note: 
PCAL laser here at End X is shuttered inside the TX module. The shutter control is turned to Local and intentionally closed, because we have stolen the RX sensor for lab measurements.


anthony.sanchez@cdsdell428: python generate_measurement_data.py --WS PS4 --date 2026-02-09
Reading in config file from python file in scripts
../../../Common/O4PSparams.yaml
PS4 rho, kappa, u_rel on 2026-02-09 corrected to ES temperature 299.7 K :
-4.701132373259706 -0.0002694340454223 2.8588448124243135e-05
Copying the scripts into tD directory...
Connected to h1daqnds1
martel run
reading data at start_time:  1454784870
reading data at start_time:  1454785410
reading data at start_time:  1454785815
reading data at start_time:  1454786310
reading data at start_time:  1454786835
reading data at start_time:  1454787210
reading data at start_time:  1454787660
reading data at start_time:  1454788220
reading data at start_time:  1454788740
Ratios: -0.46019480202307234 -0.46642274644534126
writing nds2 data to files
finishing writing
Background Values:
bg1 =        9.788561; Background of TX when WS is at TX
bg2 =        4.347145; Background of WS when WS is at TX
bg3 =        9.849034; Background of TX when WS is at RX
bg4 =        4.403818; Background of WS when WS is at RX
bg5 =        9.795756; Background of TX
bg6 =        0.716216; Background of RX

The uncertainty reported below are Relative Standard Deviation in percent 

Intermediate Ratios
RatioWS_TX_it      = -0.460195;
RatioWS_TX_ot      = -0.466423;
RatioWS_TX_ir      = -0.454775;
RatioWS_TX_or      = -0.461187;
RatioWS_TX_it_unc  = 0.087118;
RatioWS_TX_ot_unc  = 0.081615;
RatioWS_TX_ir_unc  = 0.080454;
RatioWS_TX_or_unc  = 0.079252;
Optical Efficiency
OE_Inner_beam                      = 0.988331;
OE_Outer_beam                      = 0.989282;
Weighted_Optical_Efficiency        = 0.988806;

OE_Inner_beam_unc                  = 0.054963;
OE_Outer_beam_unc                  = 0.053369;
Weighted_Optical_Efficiency_unc    = 0.076611;

Martel Voltage fit:
Gradient      = 1636.958979;
Intercept     = 0.082747;


 Power Imbalance = 0.986647;

Endstation Power sensors to WS ratios::
Ratio_WS_TX                        = -1.079194;
Ratio_WS_RX                        = -1.393794;

Ratio_WS_TX_unc                    = 0.051228;
Ratio_WS_RX_unc                    = 0.200042;

=============================================================
============= Values for Force Coefficients =================
=============================================================

Key Pcal Values :
GS           =      -5.135100; Gold Standard Value in (V/W)             
WS           =      -4.701132; Working Standard Value             

costheta     =      0.988362; Angle of incidence
c            =      299792458.000000; Speed of Light
             
End Station Values : 
TXWS         =        -1.079194; Tx to WS Rel responsivity (V/V)
sigma_TXWS   =        0.000553; Uncertainity of Tx to WS Rel responsivity (V/V)
RXWS         =        -1.393794; Rx to WS Rel responsivity (V/V)
sigma_RXWS   =        0.002788; Uncertainity of Rx to WS Rel responsivity (V/V)

e            =        0.988806; Optical Efficiency
sigma_e      =        0.000758; Uncertainity in Optical Efficiency

Martel Voltage fit : 
Martel_gradient         =        1636.958979; Martel to output channel (C/V)
Martel_intercept   =        0.082747; Intercept of fit of     Martel to output (C/V)

Power Loss Apportion : 
beta          =        0.998895; Ratio between input and output (Beta)  
E_T          =        0.993838; TX Optical efficiency 
sigma_E_T          =        0.000381; Uncertainity in TX Optical efficiency 
E_R          =        0.994937; RX Optical Efficiency 
sigma_E_R          =        0.000381; Uncertainity in RX Optical efficiency 

Force Coefficients : 
FC_TxPD          =        7.890432e-13; TxPD Force Coefficient 
FC_RxPD          =        6.178607e-13; RxPD Force Coefficient 
sigma_FC_TxPD          =        5.070187e-16; TxPD Force Coefficient 
sigma_FC_RxPD          =        1.259006e-15; RxPD Force Coefficient 
data written to ../../measurements/LHO_EndX/tD20260210/
 

 

Images attached to this report
Non-image files attached to this report
Comments related to this report
anthony.sanchez@LIGO.ORG - 16:32, Tuesday 10 February 2026 (89105)

Obligitory before and after beam spot pics. 

The problem we saw on measurement #7 where we saw a gap in the data was a DAQ restart which cuased the H1:CAL-INJ_MASTER_SW to turn back on. Which then caused H1:CAL-INJ_MASTER_OUTPUT so have a signal. So in the future if we see something like that again we should check the status of those CAL Line Injection switches before continuing again, as it apparently may increase our error bars. 

 

Images attached to this comment
Non-image files attached to this comment
Displaying report 1-1 of 1.