JAC work Friday Feb/20/2026 (Jennie, Rahul, Keita)

Modulation index measurement for 45M and 9M, they're healthy.

1W into JAC, no WFS for IMC, ITMY single bounce. Scanned OMC with both 45MHz minimal power (~4dBm) and 9MHz full (~27dBm), then both in full power, then only 45MHz in full (see screen shot).

Jennie will post the modulation index later, but the peaks look healthy to me.

The alignment into IMC was rather off in PIT and the guardian had a hard time locking IMC (I changed the lock threshold in the guardian). We didn't move MC, didn't bother to do any thorough investigation, but either JAC or MC mirrors moved. Maybe we have to lock IMC, use WFS for MC, and steer JM3 and see if the MC mirrors will be driven far from where they are. If they are we might have to touch up in-chamber alignment again.

JAC TRANS BS was swapped with the real one (laser window with AR only on one surface).

We replaced the JAC TRANS BS (which was a temporary high reflector until today) with the real one that is just a bare glass (the reflectivity is 7% or so depending on AOI). 

We locked JAC with RF, was able to see the beam coming to the TRANS PD but wasn't able to see the reflection of PD, so we raised the power to 1W.

Initially the beam was missing the PD because the new optic is thinner than the temporary one. We realigned the optic to steer the beam back to PD. Since we could not directly see the PD surface, we just steered the beam up and down, left and right until the PD output starts to drop, and put the beam roughly in the middle.

We were able to see the PD reflection using an IR card and an IR viewer. There were two reflection blobs (which was the case before, too),  and I moved the JAC TRANS BD in +X direction by 1/4~3/8" to catch both.

Images attached to this report
Comments related to this report
jennifer.wright@LIGO.ORG - 15:41, Monday 23 February 2026 (89233)

See results here (alolg #89230).

Displaying report 1-1 of 1.