Displaying report 1-1 of 1.
Reports until 18:52, Tuesday 10 December 2013
H1 ISC
alexan.staley@LIGO.ORG - posted 18:52, Tuesday 10 December 2013 - last comment - 14:22, Friday 13 December 2013(8898)
ALS Fiber Distribution Chassis S1202528

As noted in alog6341, the gain on the Dual PD Amp board was set to 30dB (photo 1). I have reduced the gain to 10dB (photo 2). However, I still see saturation at 10V in the external PD monitor. Tomorrow I will try reducing the gain to 0dB.  

Images attached to this report
Comments related to this report
alexan.staley@LIGO.ORG - 11:14, Thursday 12 December 2013 (8923)

I have reset the internal PD gain to 30dB (since we were never saturating there), and set the external PD gain to 0dB.

For the external PD:

Transimpedance = 20kOhm

Responsivity = .268A/W

Power @ ext PD = 0.93mW (w/ a drift of 7% of the ref cav alignment)

Gain = 0dB

Volts = (resp) x (power) x (trans) x (gain) = 5V

alexan.staley@LIGO.ORG - 14:22, Friday 13 December 2013 (8948)

...Ignore above calculation for external PD...

Displaying report 1-1 of 1.