Displaying report 1-1 of 1.
Reports until 13:28, Friday 06 March 2026
H1 IOO (IOO, ISC)
masayuki.nakano@LIGO.ORG - posted 13:28, Friday 06 March 2026 (89402)
JAC LSC loop design

Summary

The JAC length servo was designed to set the unity gain frequency (UGF) at 400 Hz. Additional low-frequency boost was implemented to improve suppression below 50 Hz. The open loop gain (OLG) was measured and compared with the servo model.

Details

 

Images attached to this report