Displaying report 1-1 of 1.
Reports until 15:52, Friday 06 March 2026
H1 SUS
marc.pirello@LIGO.ORG - posted 15:52, Friday 06 March 2026 - last comment - 16:23, Friday 06 March 2026(89411)
MC1 Coil Driver Swap

Per WP13076 we replaced the coil driver for MC1 due to suspicion it was causing MC1 to jump.  The coil driver in question glitched on TOP3.  Referencing D0902810-v12, the chassis in question is U41 on SUS-C4, we exchanged it with a spare.

Old SN - S1001097, New SN - S1100194

Shelia will retest the signal chain to see if this solves the issue.

Comments related to this report
ryan.short@LIGO.ORG - 16:23, Friday 06 March 2026 (89414)

It did not, at least with comparing a before/after transfer function. See alog89409.

Displaying report 1-1 of 1.