WP13077 Replace suspect first LIGO-DAC in h1sush12
Sheila, Marc, Erik, Dave:
We replaced the first LIGO-DAC in h1sush12's IO Chassis. Its ribbon cable and interface card were also replaced.
Replacement parts were removed from the DTS x7eetest1 system.
No DAQ restart was required.
JM1 and JM3 moved after this restart because of some old values in SDF for their alignment sliders, so once things were brought back up, Sheila and I realigned the suspensions and I accepted their alignment offsets in SDF. Screenshot attached.
Old Serial numbers
DAC: S2500460
Interface card: S2500449
New serial numbers:
DAC: S2500445
Interface card: 34924