MC2 M3 can actually actuate again

Daniel, Marc, Sheila, RyanC, Camila, Jeff, Oli

MC2 M3 wasn't actuating (89434) and we traced it back to its DAC cable in SUS-C2 U28 card slot #5. The cable was halfway coming off. This is because there were no jack screws to screw the cables into, so over time gravity had been pulling the heavy cable out. We took a couple extra jack screws from an unused port and used them to secure the plug in place. Once we did this, we were able to actuate with MC2 M3 again and we just locked the IMC.

There are many other cables in the CER that aren't properly screwed into their ports. We pressed them in but we will need to add jack screws to them before we have something like this happen again! 