Displaying report 1-1 of 1.
Reports until 11:58, Friday 13 December 2013
H1 ISC
christopher.wipf@LIGO.ORG - posted 11:58, Friday 13 December 2013 (8945)
ASC front end model updated

(Keiko, Chris)

The h1asc front end is now running with the latest version of the model. The previous version had been copied from L1 by Kiwamu back in May. Since then an Initial ALignment (IAL) system for the arm cavities (a dither scheme using the ALS green light) was added to h1asc by Stefan, but no other significant changes were made. Meanwhile the ASC model has been actively developed at LLO. Our goals were to update this model to track all the LLO changes, to merge in the IAL subsystem, and to start using library parts (which make it easier to verify that the LLO and LHO models are in fact the same).

Here's what's new:

Displaying report 1-1 of 1.