Improve IMC WFS RF phasing

I was looking at the correlated spectra of the IMC WFS segments and minimizing the q-signals.

Attached: screenshot of new values and spectra.

Images attached to this report
Non-image files attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 14:53, Tuesday 10 March 2026 (89458)

I made a template to check this phasing, it's in userapps/ioo/h1/dtt/IMC_wfs_phase.xml

Also, we used to use LSC_EXTRA_AO_2 for putting excitations into the common mode or IMC board, that channel still exists but it is now used for JAC locking.  So, instead we should use EXTRA_AO_3 from now on. 