Displaying report 1-1 of 1.
Reports until 16:12, Thursday 12 March 2026
H1 SUS
thomas.roocke@LIGO.ORG - posted 16:12, Thursday 12 March 2026 (89487)
QOSEM Flag Gluing
[Tom R, Ibrahim]

We glued 6x of the QOSEM flags, attaching the lens (D2500277) to the aluminium body (D2500253). This was done using a jig (D2600054) to ensure the lenses were aligned to the body of the flag. We used EP30.

Only a tiny drop of glue is required, and was applied directly to the lip of the body using a thin wire. The flags will be left to dry overnight before another batch of 6 will be glued.
Images attached to this report
Displaying report 1-1 of 1.