Reports until 16:12, Thursday 12 March 2026
H1 SUS
thomas.roocke@LIGO.ORG - posted 16:12, Thursday 12 March 2026 - last comment - 07:27, Tuesday 17 March 2026(89487)
QOSEM Flag Gluing
[Tom R, Ibrahim]

We glued 6x of the QOSEM flags, attaching the lens (D2500277) to the aluminium body (D2500253). This was done using a jig (D2600054) to ensure the lenses were aligned to the body of the flag. We used EP30.

Only a tiny drop of glue is required, and was applied directly to the lip of the body using a thin wire. The flags will be left to dry overnight before another batch of 6 will be glued.
Images attached to this report
Comments related to this report
thomas.roocke@LIGO.ORG - 19:12, Friday 13 March 2026 (89513)
The flag gluing yesterday was successful, with a strong joint and nothing obscuring the lens itself. We continued and glued another 6x flags up, and will do 6x more next week
Images attached to this comment
corey.gray@LIGO.ORG - 07:27, Tuesday 17 March 2026 (89533)EPO

Tagging For EPO.