Reports until 22:58, Friday 13 December 2013
H1 ISC
kiwamu.izumi@LIGO.ORG - posted 22:58, Friday 13 December 2013 - last comment - 23:06, Friday 13 December 2013(8953)
PRY (power recycled half michelson) locked

[ChrisW, Stefan, Sheila, Kiwamu]

The power recycled half Michelson with ITMY, so-called PRY, was locked.

It is not so stable at this moment but it could stay locked for more than 10 seconds.

 

Alignment pf PR2 and PR3:

As advertised yesterday, indeed we were close to a good alignment. Although we got confused by the BS camera, we managed to find the fringe by steering PR2 with PR3 continuousely scaning in yaw by AWG at 0.3 Hz. The vertical alignment looked OK from the beggning and we had to mainly tweak yaw. Afte we found it, we simply maximized the amplitude of the REFLAIR_A_RF9 signals. Note that the spot motion looked quiet today as all the ISIs were on.

 

Locking settings:

sensor = REFLAIR_A_RF9_I (whose phase was adjusted to be 10.0 deg)

actuator = PR2

details = see the screenshot below

 

Mysteries and issues to be solved:

Images attached to this report
Comments related to this report
kiwamu.izumi@LIGO.ORG - 23:06, Friday 13 December 2013 (8956)

Chris has just broken my best record while I was writing the alog -- he locked PRY for 4 minutes by disabling all the high freqeuncy cut off filters and truning the BS ISI off:

Images attached to this comment