Reports until 11:43, Tuesday 17 March 2026
H1 CDS
david.barker@LIGO.ORG - posted 11:43, Tuesday 17 March 2026 - last comment - 08:28, Wednesday 18 March 2026(89541)
CDS Maintenance Summary: Tuesday 17th March 2026

WP13096 Add missing h1lsc ALS DIFF PLL channel to DAQ

Jonathan, Erik, EJ, Dave:

The missing H1:ALS-C_DIFF_PLL_CTRL_OUT_DQ channel was added to the h1lsc model's DAQ Block.

We initially just restarted h1lsc, but this caused a DAC error in h1ioplsc0 (similar to h1ascimc and h1iopasc0) which meant we had to restart all the models on h1lsc0.

A DAQ restart was required.

WP13078 Add pending slow controls and h1sush6 to DAQ

WP13094 Add JAC CAM EPICS and CHETA slow chans to DAQ

DAQ RESTART

Jonathan, Erik, EJ, Dave:

A new H1EDC.ini was created with the following changes:

H1EPICS_DIGVIDEO.ini Regenerated with JAC CAM (cam38) added (+25)

H1EPICS_ECATTCSCS.ini Added CHETA laser pwr chans (+2)

H1EPICS_ECATAUXCS.ini Added C_PZT_SHUTTER chans (+11)

H1EPICS_FEC.ini Added h1sush6 models (+97)

H1EPICS_SDF.ini Added h1sush6 models (+160)

H1EPICS_DAQ.ini Added h1sush6 models (+32)

total +327. Num chans increased from 60582 to 60909.

Erik ran puppet to officially add all the new h1sush6 models to the system (I had done some hand-editing last week). He also determined the DAQ time slot h1sush6 should used.

Jonathan got the DAQ ready for the new front end and models. He also plugged the DAQ ethernet cable into the back of h1sush6 (the Dolphin cable remains unplugged for now).

We rebooted h1sush6 to get the DAQ sending started.

Jonathan then restarted the DAQ, starting with the 0-leg. I restarted the EDC at this time.

A second 0-leg restart was required to complete the configuration.

When this was stable, the 1-leg was restarted with no issues. 

We saw two spontaneous restarts of FW0 around this time, which had been seen before. At time of writing, FW0 has been up for 90 minutes.

Updates and Cleanup

Dave:

I regenerated the CDS Overview, changing h1sush6 from NO_DAQ to NOMINAL

I had to hand edit the python code generating the H1EPICS_[FEC,SDF].ini to add the new models even when they were not yet added to the DAQ, so we only needed to restart the DAQ once.

I updated DAQSTAT and CDS_HW_STAT to expect the new FECs, Models, ADCs, DACs.

Guardian Node Loading Modified Source Code.

Ryan S:

Recent changes to lscparams.py (last modified 18:43 16mar2026) and ISC_library.py (last modified 16:55 10mar2026) meant that 22 guardian nodes were pending reloading of these files.

Ryan verified that the changes made to the source code was orthogonal to the snipets used by these nodes and reloaded to the code into them to clear up the GRD CFC flags.

Loaded 273 opt/ file checksums from /opt/rtcds/lho/h1/data/guardian_files/current
Loaded 176 nodes from /opt/rtcds/lho/h1/data/guardian_files/current.yaml

================================================================================================
Node                    Status      File            Source Date            Running Date
================================================================================================
ALIGN_IFO               NOT LOADED  lscparams.py    18:43 Mon 16mar2026    12:16 Wed 11mar2026
ALS_COMM                NOT LOADED  lscparams.py    18:43 Mon 16mar2026    13:51 Mon 16mar2026
ALS_DIFF                NOT LOADED  lscparams.py    18:43 Mon 16mar2026    10:41 Fri 13mar2026
ALS_XARM                NOT LOADED  ISC_library.py  16:55 Tue 10mar2026    08:03 Tue 03mar2026
                        NOT LOADED  lscparams.py    18:43 Mon 16mar2026    08:03 Tue 03mar2026
ALS_YARM                NOT LOADED  lscparams.py    18:43 Mon 16mar2026    14:18 Wed 11mar2026
CAMERA_SERVO            NOT LOADED  ISC_library.py  16:55 Tue 10mar2026    08:02 Tue 03mar2026
                        NOT LOADED  lscparams.py    18:43 Mon 16mar2026    08:02 Tue 03mar2026
H1_MANAGER              NOT LOADED  ISC_library.py  16:55 Tue 10mar2026    08:03 Tue 03mar2026
                        NOT LOADED  lscparams.py    18:43 Mon 16mar2026    08:02 Tue 03mar2026
IMC_LOCK                NOT LOADED  lscparams.py    18:43 Mon 16mar2026    16:55 Tue 10mar2026
INIT_ALIGN              NOT LOADED  ISC_library.py  16:55 Tue 10mar2026    08:02 Tue 03mar2026
                        NOT LOADED  lscparams.py    18:43 Mon 16mar2026    08:02 Tue 03mar2026
ISC_DRMI                NOT LOADED  ISC_DRMI.py     07:57 Tue 17mar2026    18:43 Mon 16mar2026
LASER_PWR               NOT LOADED  ISC_library.py  16:55 Tue 10mar2026    08:03 Tue 03mar2026
                        NOT LOADED  lscparams.py    18:43 Mon 16mar2026    08:03 Tue 03mar2026
LOCKLOSS_SHUTTER_CHECK  NOT LOADED  lscparams.py    18:43 Mon 16mar2026    08:02 Tue 03mar2026
OMC_LOCK                NOT LOADED  ISC_library.py  16:55 Tue 10mar2026    08:03 Tue 03mar2026
                        NOT LOADED  lscparams.py    18:43 Mon 16mar2026    08:03 Tue 03mar2026
SEI_CONF                NOT LOADED  ISC_library.py  16:55 Tue 10mar2026    08:02 Tue 03mar2026
                        NOT LOADED  lscparams.py    18:43 Mon 16mar2026    08:02 Tue 03mar2026
SEI_ENV                 NOT LOADED  ISC_library.py  16:55 Tue 10mar2026    08:03 Tue 03mar2026
                        NOT LOADED  lscparams.py    18:43 Mon 16mar2026    08:02 Tue 03mar2026
SQZ_FC                  NOT LOADED  ISC_library.py  16:55 Tue 10mar2026    08:03 Tue 03mar2026
                        NOT LOADED  lscparams.py    18:43 Mon 16mar2026    08:03 Tue 03mar2026
SQZ_MANAGER             NOT LOADED  ISC_library.py  16:55 Tue 10mar2026    08:03 Tue 03mar2026
                        NOT LOADED  lscparams.py    18:43 Mon 16mar2026    08:03 Tue 03mar2026
SUS_CHARGE              NOT LOADED  lscparams.py    18:43 Mon 16mar2026    08:02 Tue 03mar2026
TCS_ITMX_CO2_PWR        NOT LOADED  lscparams.py    18:43 Mon 16mar2026    08:03 Tue 03mar2026
TCS_ITMY_CO2_PWR        NOT LOADED  lscparams.py    18:43 Mon 16mar2026    08:03 Tue 03mar2026
TEST                    NOT LOADED  lscparams.py    18:43 Mon 16mar2026    12:07 Tue 10mar2026
THERMALIZATION          NOT LOADED  lscparams.py    18:43 Mon 16mar2026    08:02 Tue 03mar2026
TMS_SERVO               NOT LOADED  ISC_library.py  16:55 Tue 10mar2026    08:03 Tue 03mar2026
                        NOT LOADED  lscparams.py    18:43 Mon 16mar2026    08:03 Tue 03mar2026
VIOLIN_DAMPING          NOT LOADED  ISC_library.py  16:55 Tue 10mar2026    08:02 Tue 03mar2026
                        NOT LOADED  lscparams.py    18:43 Mon 16mar2026    08:02 Tue 03mar2026
================================================================================================

36 file(s) NOT LOADED
 

Comments related to this report
david.barker@LIGO.ORG - 08:28, Wednesday 18 March 2026 (89550)

Tue17Mar2026
LOC TIME HOSTNAME     MODEL/REBOOT
09:37:51 h1lsc0       h1lsc       <<< new h1lsc model, but caused tim error on IOP
09:41:09 h1lsc0       h1ioplsc0   <<< restart all models on h1lsc0
09:41:23 h1lsc0       h1lsc       
09:41:37 h1lsc0       h1lscaux    
09:41:51 h1lsc0       h1sqz       
09:42:05 h1lsc0       h1ascsqzfc  


09:44:38 h1sush6      ***REBOOT*** <<< reboot h1sush6 to add to DAQ
09:45:40 h1sush6      h1iopsush6  
09:45:53 h1sush6      h1susom0    
09:46:06 h1sush6      h1susobs    
09:46:19 h1sush6      h1susam     
09:46:32 h1sush6      h1susomcab  
09:46:45 h1sush6      h1susom1ab  
09:46:58 h1sush6      h1susom2ab  
09:47:11 h1sush6      h1susom3ab  


09:52:00 h1daqgds0    [DAQ]  <<< first 0-leg restart to add sush6
09:52:01 h1daqnds0    [DAQ]
09:52:06 h1susauxh56 h1edc[DAQ] <<< EDC restart to add sush6, cam38, latest slow-ctrls
09:52:12 h1daqgds0    [DAQ]
09:52:13 h1daqfw0     [DAQ]
09:52:13 h1daqnds0    [DAQ]
09:52:13 h1daqtw0     [DAQ]


09:58:08 h1daqgds0    [DAQ] <<< second 0-leg restart to add sush6
09:58:08 h1daqnds0    [DAQ]
09:58:15 h1daqtw0     [DAQ]
09:58:19 h1daqfw0     [DAQ]
09:58:19 h1daqtw0     [DAQ]
09:58:21 h1daqgds0    [DAQ]
09:58:21 h1daqnds0    [DAQ]


10:05:49 h1daqnds0    [DAQ] <<< restart nds0 to make its uptime postive cf GDS0.


10:07:32 h1daqdc1     [DAQ] <<< 1-leg restart to add sush6
10:07:38 h1daqfw0     [DAQ] <<< spontaneous restart FW0, no FWs running at this point
10:07:42 h1daqnds1    [DAQ]
10:07:43 h1daqdc1     [DAQ]
10:07:47 h1daqtw1     [DAQ]
10:07:49 h1daqgds1    [DAQ]
10:07:52 h1daqfw1     [DAQ]
10:07:52 h1daqnds1    [DAQ]
10:07:52 h1daqtw1     [DAQ]
10:08:01 h1daqgds1    [DAQ] <<< 2nd GDS1 restart needed


10:12:48 h1daqtw0     [DAQ] <<< restart TW0 to get its delta time positive


10:23:07 h1daqfw0     [DAQ] <<< second spontaneous FW0 restart


14:34:50 h1seih16     ***REBOOT*** <<< power cycle h1seih16 following IO Chassis power glitch
14:36:23 h1seih16     h1iopseih16 
14:36:36 h1seih16     h1hpiham1   
14:36:49 h1seih16     h1hpiham6   
14:37:02 h1seih16     h1isiham1   
14:37:15 h1seih16     h1isiham6