Reports until 16:14, Thursday 19 March 2026
H1 General
ryan.short@LIGO.ORG - posted 16:14, Thursday 19 March 2026 (89570)
Updated OPS Overview

This update has been in for a little while, but I apparently didn't document it at the time.

I've updated the OPS Overview medm screen to reflect the addition of the JAC and JM suspensions in HAM1. There's a new JAC status box above HAM1, which like the IMC, will change color depending on the status of JAC for easy reference. I've also added another power readout below HAM1 to show JAC transmission; the channel used here is H1:JAC-TRANS_A_DC_POWERMON, roughly calibrated to Watts. The label for this readout is "IMC INPUT POWER," and the label for the monitor beneath the PSL now reads "JAC INPUT POWER" (even though that channel is still H1:IMC-PWR_IN_OUT16, which is a bit of a misleading channel name now).

Images attached to this report