Commissioners wanted health checks run for PR3 and PR2 to check for any suspension issues. I ran TFs for PR3 and Ibrahim ran them for PR2. Results for both suspensions look good. Results for PR3 are below, and then Ibrahim will be commenting on the info for the PR2 measurements.
Settings:
- PR3 in HEALTH_CHECK
- DAMP OFF (including estimator damping)
Data:
/ligo/svncommon/SusSVN/sus/trunk/HLTS/PR3/SAGM1/Data/2026-03-30_2115_H1SUSPR3_M1_WhiteNoise_{L,T,V,R,P,Y}_0p02to50Hz.xml
r12986
Results:
/ligo/svncommon/SusSVN/sus/trunk/HLTS/PR3/SAGM1/Results/2026-03-30_2115_H1SUSPR3_M1_ALL_TFs.pdf
/ligo/svncommon/SusSVN/sus/trunk/HLTS/PR3/SAGM1/Results/2026-03-30_2115_H1SUSPR3_M1.mat
r12987
PR2 TFs