Reports until 09:46, Wednesday 01 April 2026
H1 SQZ (SUS)
camilla.compton@LIGO.ORG - posted 09:46, Wednesday 01 April 2026 - last comment - 11:32, Thursday 02 April 2026(89729)
SQZ SUS not-repeatable alignment into FC

On Monday I had a good alignment for the FC, see 89694  and that alog's attached screenshot. Yesterday we went there and had to touch up FCs a little to get flashes. Today for the same sliders was even worse witha very PIT misalinged FC Green beam, see attached, in the same FC1 PIT slider potion, the osems were 150urad off, attached. When I brought us back to the top mass osem positions for all optics (ZM1,2,3,FC1,2 and ZM2 PSAMS) we have no green flashes in the FC, just a single pass green beam, attached

Since the good FC flashes time on Monday, the FC has moved as attached, ~100urad in Pit and ~200urad in yaw during aligned/misaligned transitions.
I see two issues here:
  1.  Why is the FC1 top mass osems drifting 150urd in 24 hours
  2.  We don't seem to be able to trust the osems as going back to them gives us no FC flashes.

Rahul did in-air TF's 75830

Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 10:04, Wednesday 01 April 2026 (89730)

Rahul found that this was because the LVEA temp around HAM7 had increased ~3degF. Betsy , Geradro noticed this was as the Megacleanroom had been turned on. Richard is now turning it off. 

camilla.compton@LIGO.ORG - 11:32, Thursday 02 April 2026 (89749)

As the temperature returned to normal with the mega clean room being turned off, our flashes degraded again. I again tried going back to the FC1 osems and the FC flashes disappeared, first attached t-cursor. I then tried going to the bottom mass WIT channels, which went the opposite direction to the osems, here the flashes were lower than when we started, second attached t-cursor. This makes us think that the best flashes are for the same slider values.

Images attached to this comment