ITMX alignment set with green baffle PD script

After the vacuum team opened up GV7 so that we can have a peek down the arm, I ran the green baffle PD scripts for the Xarm.

I did the usual misalign ITMX and ETMX, and ran the script for TMSX.  I then realigned ITMX, and ran the script for ITMX.  I then realigned ETMX and ran the script for ETMX.  

I looked at H1:ALS-X_REFL_A_DC_POWER and moved ETMX a bit to try to get some refl dips, which indicate that there are some flashes in the Xarm.  ETMX is not at all optimized, and I haven't touched TMSX since running the baffle align script on it. 

The baffle align script moved ITMX 5 or 6 urad "down" in yaw, and very little in pitch.  The attached screenshots shows times before, during, and after the baffle align script, for the ITMX sliders, top mass osems, and oplev.  The only difference between screenshots is whether cursors are included for convenience.