Displaying report 1-1 of 1.
Reports until 12:31, Friday 03 April 2026
H1 SUS (GRD, SUS)
corey.gray@LIGO.ORG - posted 12:31, Friday 03 April 2026 (89766)
Accepting SUS Slider Slider Values On SDF Before Next Vent

After all the alignment tweaks (from recent Round 2 of HAM1-JAC & SQZ work), this morning Betsy requested we record how our H1 alignment looks. Sheila mentioned noting the SUS sliders is the best way to do this, and using SDF can take care of this for us.  Guardian does not touch SUS slider values and they (for the most part) are Not Monitored by SDF.  So Accepting these SUS slider values is a good for maintaining this prefered alignment.

To capture where we are "slider-wise", went through the exercise of ACCEPTING all SUS Slider Values for H1.  Will go through SDF_OVERVIEW.adl, and open each SUS SDF Table to ACCEPT the slider values. 

The Process:  For each SUS SDF table, I will:

List of All SUS SDF Tables This Was Done For:

NOTES:

Attaching a screenshot of IFO_ALIGN_COMPACTEST.adl from earlier this morning.  (Note:  MC2, ETMy, & SRM are listed as MISALIGN from Guardian [I pointed this out to Sheila, but this is when Sheila said it's fine since Guardian doesn't change these slider channels]).

**Sheila will probably touch some Squeezer-related sliders this afternoon---This would be for FC1 (see her alog 89771).

Images attached to this report