Displaying report 1-1 of 1.
Reports until 08:58, Tuesday 07 April 2026
H1 CDS
david.barker@LIGO.ORG - posted 08:58, Tuesday 07 April 2026 - last comment - 13:14, Tuesday 07 April 2026(89803)
h1seih7 recovery work ongoing

Erik is powering down the h1seih7 system to continue our recovery work. First up: replace the timing card to see if we can get the 16bit-DAC operational again.

Comments related to this report
erik.vonreis@LIGO.ORG - 13:14, Tuesday 07 April 2026 (89807)

I replaced the timing card, DAC 0, DAC0 adapter and ribbon cable as part of the repair.

Replacing DAC0 fixed the issue, though it's now running without problems on the test stand.  So our best guess it the card needed to be reseated.

Installed timing card SN: S2101145  firmware version 0x635

Installed DAC SN: 171013-10

Installed DAC adapter SN: S1500315

Displaying report 1-1 of 1.