Displaying report 1-1 of 1.
Reports until 17:02, Tuesday 07 April 2026
H1 CDS
david.barker@LIGO.ORG - posted 17:02, Tuesday 07 April 2026 - last comment - 07:39, Wednesday 08 April 2026(89817)
CDS Maintenance Summary: Tuesday 7th April 2026

Following the fix of the DAC problem on h1seih7 and the re-install of the 3 ADCs, we restarted the DAQ to cover the WPs:

WP13132: +1 ADC SUSB2H34

h1iopsusb2h34 fully up to date

h1suslo12 DAQ update, EDC update needed

WP13133 +1 ADC SUSAUXB2H34

h1iopsusauxb2h34 fully up to date

h1susauxb2h34 needs model changes to use new ADC (Oli)

WP13100 +3 ADC SEIH7

h1iopseih7 fully up to date

h1susauxh6 DAQ updated, EDC update needed

WP13142 SPIH23

h1spih23 DAQ updated, EDC update needed.

------------------

So all WPs have some tasks left before I can close them.

Comments related to this report
david.barker@LIGO.ORG - 07:29, Wednesday 08 April 2026 (89819)

New h1isiham7 model

Jim, Dave:

We took the opportunity during h1seih7 restarts to apply a pending change to h1isiham7. The model was built against the latest versions of the common files blend_switch_library.mdl and isihammaster_2022.adl.

this added 12 slow controls to its DAQ INI file

++: slow channel H1:ISI-HAM7_PMON_GS13_P3_CTS added to the DAQ
++: slow channel H1:ISI-HAM7_PMON_GS13_P2_CTS added to the DAQ
++: slow channel H1:ISI-HAM7_PMON_GS13_P1_CTS added to the DAQ
++: slow channel H1:ISI-HAM7_PMON_GS13_D3_CTS added to the DAQ
++: slow channel H1:ISI-HAM7_PMON_GS13_D2_CTS added to the DAQ
++: slow channel H1:ISI-HAM7_PMON_GS13_D1_CTS added to the DAQ
++: slow channel H1:ISI-HAM7_PMON_FF_L4C_P3_CTS added to the DAQ
++: slow channel H1:ISI-HAM7_PMON_FF_L4C_P2_CTS added to the DAQ
++: slow channel H1:ISI-HAM7_PMON_FF_L4C_P1_CTS added to the DAQ
++: slow channel H1:ISI-HAM7_PMON_FF_L4C_D3_CTS added to the DAQ
++: slow channel H1:ISI-HAM7_PMON_FF_L4C_D2_CTS added to the DAQ
++: slow channel H1:ISI-HAM7_PMON_FF_L4C_D1_CTS added to the DAQ
 

All ISI HAMs have been updated with the exception of h1isiham6.

david.barker@LIGO.ORG - 07:39, Wednesday 08 April 2026 (89820)

Tue07Apr2026
LOC TIME HOSTNAME     MODEL/REBOOT
09:19:56 h1seih7      ***REBOOT***  <<< Multiple reboots/restarts of h1seih7 to fix DAC FIFO-EMPTY issue
09:21:25 h1seih7      h1iopseih7  
09:21:38 h1seih7      h1isiham7   
09:42:47 h1seih7      ***REBOOT***
09:44:16 h1seih7      h1iopseih7  
09:44:29 h1seih7      h1isiham7   
09:56:37 h1seih7      ***REBOOT***
09:58:07 h1seih7      h1iopseih7  
09:58:20 h1seih7      h1isiham7   
10:21:46 h1seih7      ***REBOOT***
10:23:14 h1seih7      h1iopseih7  
10:23:27 h1seih7      h1isiham7   
10:50:12 h1seih7      ***REBOOT***
10:51:44 h1seih7      h1iopseih7  
10:51:57 h1seih7      h1isiham7   <<< New h1isiham7 model installed
11:10:01 h1susb2h34   h1suslo12   <<< First run of h1suslo12 model on h1susb2h34 using new ADC
11:11:30 h1seih7      h1susauxh6  <<< First run of h1susauxh6 on h1seih7 using the 3 new ADCs
11:15:06 h1daqgds0    [DAQ] <<< DAQ restart for all recent model changes
11:15:10 h1daqfw0     [DAQ]
11:15:11 h1daqnds0    [DAQ]
11:15:11 h1daqtw0     [DAQ]
11:15:41 h1susauxh56 h1edc[DAQ] <<< EDC restart using puppet controlled INI files 
11:23:20 h1daqdc1     [DAQ]
11:23:28 h1daqfw1     [DAQ]
11:23:28 h1daqtw1     [DAQ]
11:23:33 h1daqnds1    [DAQ]
11:23:39 h1daqgds1    [DAQ]
11:24:15 h1daqgds1    [DAQ] <<< GDS1 needed a manual restart
11:43:10 h1daqfw1     [DAQ] <<< Spontaneous FW1 restart
 

 
Mon06Apr2026
LOC TIME HOSTNAME     MODEL/REBOOT
14:42:08 h1susb13     h1iopsusb13 <<< susb13 restart to reduce SWWD trip times
14:42:22 h1susb13     h1susitmy   
14:42:36 h1susb13     h1susitmx   
14:42:50 h1susb13     h1susitmpi  
14:56:29 h1susb2h34   ***REBOOT*** <<< susb2h34 +1 ADC installed
14:58:13 h1susb2h34   h1iopsusb2h34 <<< New iop for ADC addition
14:58:26 h1susb2h34   h1susbs     
14:58:39 h1susb2h34   h1susmc2    
14:58:52 h1susb2h34   h1suspr2    
14:59:05 h1susb2h34   h1sussr2    
15:02:38 h1susauxb2h34 ***REBOOT*** <<< susauxb2h34 +1 ADC installed
15:03:41 h1susauxb2h34 h1iopsusauxb2h34 <<< New iop for ADC addition
15:03:54 h1susauxb2h34 h1susauxb2h34
15:46:41 h1seih7      ***REBOOT*** <<< seih7 +3 ADC installed
15:48:14 h1seih7      h1iopseih7  
15:48:27 h1seih7      h1isiham7   
16:03:38 h1seih7      h1iopseih7  <<< Many reboots of seih7 attempting to fix DAC FIFO-EMPTY issue
16:03:52 h1seih7      h1isiham7   
16:10:37 h1seih7      ***REBOOT***
16:12:11 h1seih7      h1iopseih7  
16:12:24 h1seih7      h1isiham7   
16:21:23 h1seih7      h1iopseih7  
16:21:36 h1seih7      h1isiham7   
16:22:35 h1seih7      h1iopseih7  
16:38:30 h1seih7      ***REBOOT***
16:46:55 h1seih7      ***REBOOT***
16:48:25 h1seih7      h1iopseih7  
16:48:38 h1seih7      h1isiham7   
17:02:45 h1seih7      ***REBOOT***
17:04:14 h1seih7      h1iopseih7  
17:04:27 h1seih7      h1isiham7   
17:18:41 h1seih7      ***REBOOT***
17:20:11 h1seih7      h1iopseih7  
17:20:24 h1seih7      h1isiham7   
 

Displaying report 1-1 of 1.