PSL Status Report Weekly FAMIS 39759

Closes FAMIS39759, last checked in alog89772


Laser Status:
    NPRO output power is 1.835W
    AMP1 output power is 70.55W
    AMP2 output power is 138.1W
    NPRO watchdog is GREEN
    AMP1 watchdog is GREEN
    AMP2 watchdog is GREEN
    PDWD watchdog is GREEN

PMC:
    It has been locked 3 days, 22 hr 40 minutes
    Reflected power = 27.2W
    Transmitted power = 104.0W
    PowerSum = 131.2W

FSS:
    It has been locked for 3 days 22 hr and 40 min
    TPD[V] = 0.4879V

ISS:
    The diffracted power is around 4.0%
    Last saturation event was 0 days 0 hours and 0 minutes ago


Possible Issues:
    PMC reflected power is high