gerardo.moreno@LIGO.ORG - posted 15:35, Thursday 09 April 2026 - last comment - 15:49, Thursday 09 April 2026(89846)
HAM3 Doors are Off

(Jordan V., Travis S., Randy T., Corey G., Gerardo M.)

The removal was somewhat cumbersome for both doors, but the doors are off HAM3, on the +Y door both O-rings popped out at the bottom of the chamber, they were easily coaxed back into the O-ring groove, both O-rings were out from 5 to 7 O'clock, both bolt holes at this location have traces of "rust".  The -Y side door was a bit more sticky, it took some time to convince the door to come loose, and we had O-rings out of the groove from 4:30 to 6:15 O'clock, both of them at one point.  They went back into the O-ring groove without a major issue.
Flange protector were installed and both C3 covers, purge is up.

Images attached to this report
Comments related to this report
corey.gray@LIGO.ORG - 15:49, Thursday 09 April 2026 (89848)EPO, VE

I ended up joining the VAC/FAC crew in the middle of their work.  Snapped some additional photos and videos when I could.

Images attached to this comment