Reports until 16:15, Thursday 09 April 2026
LHO VE (EPO, PEM, VE)
corey.gray@LIGO.ORG - posted 16:15, Thursday 09 April 2026 - last comment - 17:35, Friday 10 April 2026(89849)
BSC1 +Y Door Bolts Removed + BSC2 Dome Bolts Removed, BUT Had One Galled Dome Bolt!

(Jordan V, Corey G)

In prep for upcoming BBSS Install, "broke" bolts (which is slang for loosened them) on:

BSC1's +Y Door Bolts (mostly) Removed & Accelerometer Cable Disconnected

BSC1's door had all bolts but (4) removed.  Sadly, I removed the bottom (easy ones) bolts first and then when I got to the top bolts they were very hard to loosen because of some sag.  Additionally, their access is horrible with:  a stiffening plate for the chamber right above the rear access to these bolts, then there are cable trays also in the way, and the C3 fabric cover is draped in your face the whole time.  Jordan helped out and we were able to get the last top bolt removed.  We also loosened the (4) bolts 1-turn which is the typical procedure.

There was an accelerometer still cabled up to this door.  I disconnected the cable (labeled "PEM:BSC1_ACC_X") and stuffed the cable into the cable tray above this door.

Time lapse of me removing half the bolts in this LINK (since we only files allowed in alog have to be smaller than 15Mb.)  :(

BSC2's Dome Bolts (mostly) Removed, But Have A Galled Bolt!

BSC2's dome bolts were removed.  4-bolts were left in place (they were loosened and then tightened up a little).  One notable, is there is 1-galled dome bolt.  Jordan and I used the long wrenches to see if we could use more force to help it break loose, but no luck.  We did not try pouring some alcohol on the bolt to help as a lubricant.  The bolt is loose and has about 1-2mm of a gap on it.  So, the pros could try use even longer cheater bars, a saw cutter, or they were also chatting about a tool to cut the nut off.  At any rate, 

Images attached to this report
Comments related to this report
gerardo.moreno@LIGO.ORG - 17:35, Friday 10 April 2026 (89864)VE

(Travis S., Gerardo M.)

Travis brought his portable reciprocating saw and a couple of new blades, this little saw did the job, we were able to make a couple of cuts then used the big wrenches to break the bolt off.  Galled bolt is off!

Images attached to this comment