WP13110 Upgrade IO Chassis Timing Card Firmware and Sync Ribbon
Marc, Erik, Jeff, Tony, Dave:
The following IO Chassis were upgraded today: h1cdsh8, h1susb13, h1sush[12,56,6,7], h1seib[1,2,3], h1seih[23,45].
Models were rebuilt against RCG5.5.2 for: h1cdsh8, h1seib[1,2,3], h1seih[23,45], h1sush[56,7]
This completes the IO Chassis TC upgrades. T2600143 has been updated.
Restore h1hwsey Hartmann Wavefront Sensor Computer
TJ, Jonathan, Dave:
Last Friday I got the h1hwsey computer running again. This afternoon TJ started the HWS ETMY software on it. Just prior to this Jonathan and I stopped and disabled the dummy IOC which had been running on cdsioc0 since dec2025.