Reports until 23:24, Tuesday 14 April 2026
H1 SUS
ibrahim.abouelfettouh@LIGO.ORG - posted 23:24, Tuesday 14 April 2026 - last comment - 16:44, Wednesday 15 April 2026(89891)
ITMY ITMX and BS Oplev Trend since last DRMI

Attahed and in the table below are oplev positions for ITMY, ITMX and BS since last DRMI lock on 03/19/2026 at 11:02 PDT

  DRMI Locked Reference Latest
  11:02 PDT 03/19/26 15:00 PDT 04/14/26
BS P Oplev 2.10 0
BS Y Oplev -25.92 0
BS Sum Oplev 20215.30 19605.8
IX P Oplev -10.70 -3.64
IX Y Oplev 5.10 -1.2
IX Sum Oplev 3188.52 4.7
IY P Oplev -26.65 42.5
IY Y Oplev -3.22 22.92
IY Sum Oplev 7904.27 4731.59

Note 1: The BS Oplev Damping loops were still on during some FARO work and were shaking the BS. We turned these off on morning of April 14.

Note 2: The right-most T-cursor marks the corner-station vent

Images attached to this report
Comments related to this report
ibrahim.abouelfettouh@LIGO.ORG - 16:02, Wednesday 15 April 2026 (89907)

Note that gate valve closure means that IX oplevs would read a 0 sum. This is expected.

betsy.weaver@LIGO.ORG - 16:44, Wednesday 15 April 2026 (89908)
Also, since this alog, Jeff/Ibrahim flipped the BS OPLEV Damping Servo OFF via the damping filter bank buttons, and re-turned-on the output buttons of the main banks, so those Pit/Yaw channel values bounced back up from 0 to more reasonable values.