Displaying report 1-1 of 1.
Reports until 15:29, Thursday 16 April 2026
H1 CDS
david.barker@LIGO.ORG - posted 15:29, Thursday 16 April 2026 - last comment - 13:25, Friday 17 April 2026(89923)
ISI Watchdog Trip Plotting Working Again

FRS37572 ISI HAM and BSC WD Plots Not Working

Ryan C, Erik, Dave:

The MEDM buttons to plot the latest ISI WD trips (see attached) have not been working for some time.

We found the issue was due to the wd_plot python code running in the conda environment had pydv issues, but if ran in native debian it worked.

Fixing the conda pydv issue would take significant resouces, so we chose to change the MEDM launcher to explicitly run local /usr/bin/python3.

The common MEDM file ISI_CUST_CHAMBER_WATCHDOG.adl in the isi/comon/medm/[hamisi, bscisi]/ directories were changed accordingly.

I tested with HAM2 and BSC3.

Images attached to this report
Comments related to this report
brian.lantz@LIGO.ORG - 13:25, Friday 17 April 2026 (89939)

Thanks Dave, those plots are useful diagnostic tools.
I dropped a note in the LLO log so we can be sure this fix gets used at both sites 

-Brian

Displaying report 1-1 of 1.