Displaying report 1-1 of 1.
Reports until 14:22, Tuesday 28 April 2026
H1 SUS
rahul.kumar@LIGO.ORG - posted 14:22, Tuesday 28 April 2026 - last comment - 14:27, Tuesday 28 April 2026(90035)
HAM3 chamber vent work - SLiC, BAFFLE ASSY attached to both PR2 and MC2

Mitchell, Rahul

This morning we entered HAM3 chamber and attached the baffles (for stray light control) to both PR2 (HSTS) and MC2 (HSTS) suspensions. The baffle assembly design is shown D1700257_V5. These baffles were attached (directly mounted on the HSTS structure) on both the sides of the optic, i.e  HR and AR side.

Before attaching the baffles I inspected both the optics and they looked nice and clean, hence didn't needed any First Contact cleaning. 

I am attaching pictures below for reference.

We found that both PR2 and MC2 had two missing 1/4-20 threads on the HR side for attaching the mounting rail (D1700249_v1) of the baffle (Mitchell will attach a picture showing the same). Typically, these rail need four holes on the structure for securing them. However, we used the lower two threaded holes for attaching these mounting rail and they were rigidly secured. On the DCC I found that both PR2 and MC2 have D020023_V3 of the HSTS_Structural Weldment Assembly, latest D020023_V7 has more holes on the frame.

We also noted that one of the Siskiyou mount is very close to the MC2 baffle (AR side) as shown in the picture here. However, I can confirm that they are not touching and there is a decent amount of clearance between them. 

I still need to perform health checks on both the suspensions to rule out any rubbing and will post the results as a comment over here.

Note - counts on dust monitor were in single digit before and after entering/exiting the chamber (Thanks to Ryan C for arranging this). 

Images attached to this report
Comments related to this report
rahul.kumar@LIGO.ORG - 14:25, Tuesday 28 April 2026 (90036)

WP13211 closed. 

mitchell.robinson@LIGO.ORG - 14:27, Tuesday 28 April 2026 (90037)

Pictures of the HR side of PR2. No upper mounting holes for the HRST Baffle rail.

Images attached to this comment
Displaying report 1-1 of 1.