Displaying report 1-1 of 1.
Reports until 16:46, Tuesday 28 April 2026
H1 CDS
david.barker@LIGO.ORG - posted 16:46, Tuesday 28 April 2026 - last comment - 16:48, Tuesday 28 April 2026(90043)
h1suslo12 model now temporarily running as the BBSS model alongside the original (but slightly modified) BSFM h1susbs model

WP13213 Jeff, Tom, Oli, Dave:

h1susbs (the original BSFM model) was changed slightly to no longer drive the 2nd LIGO-DAC chans 08-11. This frees these up for use by the BBSS model. At the same time 4 IPC senders and 11 IPC receivers were removed.

Instead of replacing h1suslo12 with a brand new h1susbbss model, with all the associated RGC/DAQ/puppet changes, we chose to keep the h1suslo12 model essentially in name only, but change its function to drive the BBSS and test QOSEMS.

To do this, Oli changed the h1susbbss.mdl file to:

 - use h1suslo12's dcuid=188

 - remove all IPC senders

 - reduce the number of DAC channels, only using those freed up by the h1susbs changes

This approach means the H1.ipc and testpoint.par files are unchanged. The H1SUSLO12.txt filterfile and safe.snap files are substantially changed, but these had not been commissioned. The H1SUSLO12.ini file was also essentially rewritten for BBSS with the exception of some FEC channels.

There were no issues with rebuilding and installing the new h1susbs and h1suslo12 models. The old versions were stopped before the new ones were started because we are swapping DAC drives between these models.

DAQ Restart

The DAQ was restarted for the model changes. There were no issues found.

CDS Overview

The h1suslo12 entry on the CDS Overview has a new color/label to denote its current usage as the BBSS model. Also note the removal of some IPC senders from h1susbs means we have continuous IPC receive errors on the h1susmc2 and h1seiproc models.

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 16:31, Tuesday 28 April 2026 (90044)

Summary of h1susbs DAQ changes:

Total number of DAQ changes = 48
(0 additions, 48 deletions)
 
IPC: 11 Removed Receivers:
     H1:FEC-31_IPC_ASC_BS_PIT_SUSBS
     H1:FEC-31_IPC_ASC_BS_YAW_SUSBS
     H1:FEC-31_IPC_ASC_SUS_BS_PIT_DITHER
     H1:FEC-31_IPC_ASC_SUS_BS_YAW_DITHER
     H1:FEC-31_IPC_ISI_BS_SUSPOINT_BS_L_OUT_IPC
     H1:FEC-31_IPC_ISI_BS_SUSPOINT_BS_P_OUT_IPC
     H1:FEC-31_IPC_LSC_BS_L_SUSBS
     H1:FEC-31_IPC_LSC_TRIG_IFO_PCIE
     H1:FEC-31_IPC_SUS_MC2_2_BS_M1_BIO
     H1:FEC-31_IPC_SUS_MC2_2_BS_M2_BIO
     H1:FEC-31_IPC_SUS_MC2_2_BS_M3_BIO


IPC: 4 Removed Senders
     H1:FEC-31_IPC_SUS_BS_2_MC2_M1_BIO NOTE: receiver in model(s) ['h1susmc2']
     H1:FEC-31_IPC_SUS_BS_2_MC2_M2_BIO NOTE: receiver in model(s) ['h1susmc2']
     H1:FEC-31_IPC_SUS_BS_2_MC2_M3_BIO NOTE: receiver in model(s) ['h1susmc2']
     H1:FEC-31_IPC_SUS_BS_M1_LOCK_L NOTE: receiver in model(s) ['h1seiproc']
 

david.barker@LIGO.ORG - 16:32, Tuesday 28 April 2026 (90045)

Summary of h1suslo12 DAQ changes (now BBSS):

Total number of DAQ changes = 4510
(2932 additions, 1578 deletions)

No IPC changes

david.barker@LIGO.ORG - 16:48, Tuesday 28 April 2026 (90046)

Tue28Apr2026
LOC TIME HOSTNAME     MODEL/REBOOT
15:05:36 h1susb2h34   h1susbs     <<< reduced BSFM model
15:06:02 h1susb2h34   h1suslo12   <<< repurposed as BBSS model


15:13:55 h1daqgds0    [DAQ] <<< 0-leg for model changes
15:14:02 h1daqfw0     [DAQ]
15:14:02 h1daqtw0     [DAQ]
15:14:03 h1daqnds0    [DAQ]
15:16:57 h1daqdc1     [DAQ] << 1leg restart
15:17:07 h1daqfw1     [DAQ]
15:17:08 h1daqtw1     [DAQ]
15:17:10 h1daqnds1    [DAQ]
15:17:18 h1daqgds1    [DAQ]
15:17:44 h1daqgds1    [DAQ] <<< gds1 needed a restart
 