cds_ezcaread
Per Dave's recommendation, we have removed the cds_ezcaread "disconnected" at the top levels of our real time models (they were causing troubles to record the slow channels under the latest RCG version).

Those were used in the early days to monitor the suspensions watchdog states. This feature is now done through IPC_CPIE but the old ezcaread were still in there.

I found ezcaread blocks in all models except isiitmx and hpiitmx. Did not find any in the ham-isi and ham-hepi models. 

Dave said there's no rush to recompile for now (work permit will be issued when the models will be recompiled and installed)


Side note: we still have to implement the suspension watchdogs monitoring through IPC in the hpiitmx model.