Displaying report 1-1 of 1.
Reports until 17:36, Wednesday 18 December 2013
H1 ISC
christopher.wipf@LIGO.ORG - posted 17:36, Wednesday 18 December 2013 (9014)
EX cabling

I fixed the fast readbacks for the common mode boards and the power monitor PDs at the X end.  (Their AA chassis was plugged into the wrong ADC.)

The "Red Path" PDs on the End X overview screen are not working yet.  But they should be, as soon as Cable 86 (which carries them from the field rack to the AA chassis) is installed.  It's on Fil's to-do list.

Displaying report 1-1 of 1.