Displaying report 1-1 of 1.
Reports until 17:25, Wednesday 06 May 2026
H1 COC
ibrahim.abouelfettouh@LIGO.ORG - posted 17:25, Wednesday 06 May 2026 - last comment - 17:19, Thursday 07 May 2026(90147)
BBS01: Mystery spots on AR Side + Cleaning

Ibrahim, Betsy, Rahul, GariLynn

Following AR side first contact removal, we did our first flashlight inspection of the AR side (S2) of the optic. We found that there were 4 spots of varying size all under 1mm, perfectly circular. They seem to look like water (look at image). We contacting COC (GariLynn), who informed us this may be some coating defect. Nontheless, we tried cleaning it.

There are 2 smaller spots on the side of the optic (see image). There are 2 other spots near the center, with one being pretty dead on-center.

First, we used acetone with a cotton swab to wet two spots (the ones on the side). This didn't work and the spots were still there.

Second, we followed T1800350 to clean two spots with water, then immediately apply first contact. This didn't work either.

We will continue to clean spots with water tomorrow. Images below.

Images attached to this report
Comments related to this report
ibrahim.abouelfettouh@LIGO.ORG - 17:19, Thursday 07 May 2026 (90160)

Check alog 90159 for continuation of this story.

Displaying report 1-1 of 1.