BBS01: Mystery spots on AR Side Imaged

Ibrahim, Betsy

Today, Betsy and I set up a Dino-Lite to image the spots we found yesterday (alog 90147).

Below are photos including before and after cleaning - according to the names of the files. None of the spots seemed to change after cleaning.

We also cleaned the spot that's in the center (not imaged with dino-lite) but it also did not go away.

Current most likely hypothesis is a coating defect due to circular nature of the spots and the resistance to cleaning.

Images attached to this report
Comments related to this report
betsy.weaver@LIGO.ORG - 22:45, Thursday 07 May 2026 (90165)

All of the spot pictures are un-cropped since the dino-lite was jigged to be roughly the same picture size and therefore show the relative spot sizes from one picture to the next.  The last picture has a 2mm disc shown for scale (a banana was way too big, thankfully).  The attached shows roughly where the 4 spots are.  From some estimating on the pictures, spot sizes are roughly:

1: 0.5mm diam, bottom of the optic

2: 0.3mm diam, bottom of the optic

3: 0.6mm diam, centerline, but left a few inches

4: No pictures, almost dead center of optic so riskier to photograph, but much smaller like 0.1-0.2mm diam when visually comapred to the other spots

Images attached to this comment
corey.gray@LIGO.ORG - 09:27, Friday 08 May 2026 (90168)EPO

tagging for photos