vertex interferometer alignment: PRMI finally flashing

PRMI is finally aligned and it is now flashing. This should help us to find the POP beam because of higher intra-cavity power and reasonable alignment.

After PRMI was coarsely aligned, I went to ISCT1 and quickly looked for the POP beam, but no beam was found. I also toggeled the HAM1 POP beam diverter, but it didn't help.

The above plot is an exmaple of time series where you can see that ASC_POP_A goes up to more than 100 counts because of the recycling.

 

Alignment:

 

Images attached to this report
Comments related to this report
keita.kawabe@LIGO.ORG - 08:15, Thursday 19 December 2013 (9019)

Sadly, we're finding that aLIGO OLs are not as reliable as OSEMs as a long term reference, just like in iLIGO. According to Kiwamu, all previous PR-X alignment efforts were with the BS angle restored using OLs, not M0 BOSEMs.

keita.kawabe@LIGO.ORG - 08:47, Thursday 19 December 2013 (9020)

Richard says that OLs were fine in iLIGO as far as nobody touched anything.